Balkparameters
Voor benuttingsgraad η = M_Ed / M_b,Rd
M_cr formula — EN 1993-1-1 Annex F (Eq F.2)
M_cr = C1 · (π²EIz/(kL)²) · √[ Iw/Iz
+ (kL)²·G·It/(π²·E·Iz)
+ (C2·zg)² ] − C2·zg
C1 — moment diagram factor (load case)
C2 — load application height factor
k — effective length factor (rotation BC)
k_w — effective length factor (warping BC)
zg — load height above shear centre (mm)
→ top flange: +h/2 (destabilising)
→ shear centre: 0
→ bottom flange: −h/2 (stabilising)
E = 210,000 N/mm² G = 81,000 N/mm²
Table 6.4 — LTB Buckling Curve Selection
| Section type | h/b | Curve | α_LT |
|---|---|---|---|
| Rolled I/H | ≤ 2 | b | 0.34 |
| Rolled I/H | > 2 | c | 0.49 |
| Welded I | ≤ 2 | c | 0.49 |
| Welded I | > 2 | d | 0.76 |
§6.3.2.3 (rolled — modified, β=0.75, λLT,0=0.4)
M_cr
259.25kNm
λ̄_LT
1.3393
χ_LT
0.462
M_b,Rd
214.87kNm
Kritisch moment M_cr
C1 (momentdiagram factor)1.13
C2 (lastpunt factor)0.45
k (rotatie randvoorwaarde)1
k_w (wolving randvoorwaarde)1
z_g (mm)0 mm
M_cr (kNm)259.25 kNm
Kipcontrole
λ̄_LT1.3393
λ̄_LT,0 (kipplateau)0.4
Knikklassec
α_LT (onvolkomenheidsfactor)0.49
φ_LT1.4028
χ_LT0.462
f-factor (§6.3.2.3)0.9875
M_c,Rd (zonder kip, kNm)465.05 kNm
M_b,Rd (kip, kNm)214.87 kNm
Doorsnedeklasse1
γ_M11
χ_LT reduction factor — Buckling curves a/b/c/d
a — αLT=0.21
b — αLT=0.34
c — αLT=0.49
d — αLT=0.76
Current λ̄_LT / χ_LT
Draagvermogen vs. Onstutte Lengte
M_b,Rd (kNm) vs. onstutte lengte. Huidige L gemarkeerd.
E-mail rekenrapport — Voer uw e-mailadres in voor een kipberekening rapport.
Gerelateerde Tools
LTB op alle balken in een tekeningenset
Upload uw PDF. FrameAI leest alle leden, controleert §6.3.2 kip + §6.3.1 knikking + §6.2 doorsnede en levert een fabricagerapport in 90 seconden.
Volledige pipeline →