Free Tool · EN 1993-1-8 §4.5.3 · No Sign-up
Compute required throat a, design resistance Fw,Rd and stresses σ⊥, τ⊥, τ∥ per EN 1993-1-8 §4.5.3. Directional (§4.5.3.2) and simplified (§4.5.3.3) methods. Reverse mode solves minimum throat for given load. No sign-up.
| Check | η | Limit | Result |
|---|---|---|---|
| §4.5.3.2 Combined | 0.2% | ≤ 100% | PASS ✓ |
| §4.5.3.2 σ⊥ cap | 0.1% | ≤ 100% | PASS ✓ |
| Steel grade | β_w (Table 4.1) | f_u (MPa) |
|---|---|---|
| S235 | 0.8 | 360 |
| S275 | 0.85 | 430 |
| S355 | 0.9 | 490 |
| S420 | 1 | 520 |
| S460 | 1 | 560 |
Export weld calculation report
Enter your email to receive a formatted EN 1993-1-8 weld sizing report.
Related Tools
Need weld sizing across your whole drawing set?
FrameAI extracts every weld from your structural PDF and auto-sizes flange, web and stiffener welds against EN 1993-1-8 — producing a complete fabrication weld schedule.
See Full Connection Design →