DIN EN 1993-1-1 Stahlprofil · Querschnitt von HEM
HEM 200 — Section Properties & EN 1993-1-1 Classification
HEM 200 is a Klasse 1 — Plastisch
Profil in S355 (fy = 355 MPa).
h = 220 mm
b = 206 mm
A = 8,800 mm²
Iy = 10,640 cm⁴
Wpl,y = 1160 cm³
EN / NL / DE annexes
Keine Anmeldung · Kostenlos
Querschnittsklassifizierung (DIN EN 1993-1-1 Tabelle 5.2)
Steel Grade
γM0
Web (c/tw )
Flange (c/tf )
Class
S235
1.00
8.93 → 1
3.1 → 1
Class 1
S235
1.10
8.93 → 1
3.1 → 1
Class 1
S235
1.05
8.93 → 1
3.1 → 1
Class 1
S275
1.00
8.93 → 1
3.1 → 1
Class 1
S275
1.10
8.93 → 1
3.1 → 1
Class 1
S275
1.05
8.93 → 1
3.1 → 1
Class 1
S355
1.00
8.93 → 1
3.1 → 1
Class 1
S355
1.10
8.93 → 1
3.1 → 1
Class 1
S355
1.05
8.93 → 1
3.1 → 1
Class 1
S420
1.00
8.93 → 1
3.1 → 1
Class 1
S420
1.10
8.93 → 1
3.1 → 1
Class 1
S420
1.05
8.93 → 1
3.1 → 1
Class 1
S460
1.00
8.93 → 1
3.1 → 1
Class 1
S460
1.10
8.93 → 1
3.1 → 1
Class 1
S460
1.05
8.93 → 1
3.1 → 1
Class 1
Property Value
h (mm) 220
b (mm) 206
tw / tf (mm) 15 / 25
r (mm) 18
A (mm²) 8,800
Iy (cm⁴) 10,640
Iz (cm⁴) 3,650
Wel,y (cm³) 968
Wpl,y (cm³) 1160
iy / iz (mm) 110 / 64.4
Bemessungswiderstände · γM0
Resistance Value
Npl,Rd 2,068 kN
Vpl,Rd 597 kN
Mpl,Rd 272.6 kNm
Mel,Rd 227.5 kNm
Resistance Value
Npl,Rd 1,880 kN
Vpl,Rd 542.7 kN
Mpl,Rd 247.8 kNm
Mel,Rd 206.8 kNm
Resistance Value
Npl,Rd 1,969.5 kN
Vpl,Rd 568.6 kN
Mpl,Rd 259.6 kNm
Mel,Rd 216.6 kNm
Resistance Value
Npl,Rd 2,420 kN
Vpl,Rd 698.6 kN
Mpl,Rd 319 kNm
Mel,Rd 266.2 kNm
Resistance Value
Npl,Rd 2,200 kN
Vpl,Rd 635.1 kN
Mpl,Rd 290 kNm
Mel,Rd 242 kNm
Resistance Value
Npl,Rd 2,304.8 kN
Vpl,Rd 665.3 kN
Mpl,Rd 303.8 kNm
Mel,Rd 253.5 kNm
Resistance Value
Npl,Rd 3,124 kN
Vpl,Rd 901.8 kN
Mpl,Rd 411.8 kNm
Mel,Rd 343.6 kNm
Resistance Value
Npl,Rd 2,840 kN
Vpl,Rd 819.8 kN
Mpl,Rd 374.4 kNm
Mel,Rd 312.4 kNm
Resistance Value
Npl,Rd 2,975.2 kN
Vpl,Rd 858.9 kN
Mpl,Rd 392.2 kNm
Mel,Rd 327.3 kNm
Resistance Value
Npl,Rd 3,696 kN
Vpl,Rd 1,066.9 kN
Mpl,Rd 487.2 kNm
Mel,Rd 406.6 kNm
Resistance Value
Npl,Rd 3,360 kN
Vpl,Rd 969.9 kN
Mpl,Rd 442.9 kNm
Mel,Rd 369.6 kNm
Resistance Value
Npl,Rd 3,520 kN
Vpl,Rd 1,016.1 kN
Mpl,Rd 464 kNm
Mel,Rd 387.2 kNm
Resistance Value
Npl,Rd 4,048 kN
Vpl,Rd 1,168.6 kN
Mpl,Rd 533.6 kNm
Mel,Rd 445.3 kNm
Resistance Value
Npl,Rd 3,680 kN
Vpl,Rd 1,062.3 kN
Mpl,Rd 485.1 kNm
Mel,Rd 404.8 kNm
Resistance Value
Npl,Rd 3,855.2 kN
Vpl,Rd 1,112.9 kN
Mpl,Rd 508.2 kNm
Mel,Rd 424.1 kNm
Pro feature
Vollständiger Portalrahmen mit 50+ Profilen?
FrameAI Pro verarbeitet Ihren kompletten PDF-Zeichnungssatz — extrahiert alle Profile, klassifiziert jeden Querschnitt, berechnet Knickstäbe und Verbindungen, und generiert werkstattfertige Zeichnungen mit DSTV NC1 Dateien.
Pro-Pläne ansehen →
← ← Zurück zum Rechner
HEM 200 — Querschnittsklassifizierung & Widerstände
Diese Seite zeigt vorausberechnete DIN EN 1993-1-1 Bemessungswerte für das HEM 200 HEM-Profil. Die maßgebende Querschnittsklasse ist 1 (Klasse 1 — Plastisch), die bestimmt, ob das Profil sein volles plastisches Moment entwickeln kann (Klasse 1–2) oder auf das elastische Moment beschränkt ist (Klasse 3–4). Npl,Rd, Vpl,Rd, Mpl,Rd und Mel,Rd sind für alle Kombinationen von Stahlgüte (S235 bis S460) und Nationalem Anhang (EN γM0=1,00, NL γM0=1,10, DE γM0=1,05) angegeben.