EN 1993-1-1 Steel Section · Section of HEA
HEA 400 — Section Properties & EN 1993-1-1 Classification
HEA 400 is a Class 2 — Compact
section in S355 (fy = 355 MPa).
S235: Class 1
S275: Class 1
h = 390 mm
b = 300 mm
A = 12,580 mm²
Iy = 45,070 cm⁴
Wpl,y = 2654 cm³
EN / NL / DE annexes
No sign-up · Free forever
Cross-Section Classification (EN 1993-1-1 Table 5.2)
Steel Grade
γM0
Web (c/tw )
Flange (c/tf )
Class
S235
1.00
27.09 → 1
6.18 → 1
Class 1
S235
1.10
27.09 → 1
6.18 → 1
Class 1
S235
1.05
27.09 → 1
6.18 → 1
Class 1
S275
1.00
27.09 → 1
6.18 → 1
Class 1
S275
1.10
27.09 → 1
6.18 → 1
Class 1
S275
1.05
27.09 → 1
6.18 → 1
Class 1
S355
1.00
27.09 → 2
6.18 → 1
Class 2
S355
1.10
27.09 → 2
6.18 → 1
Class 2
S355
1.05
27.09 → 2
6.18 → 1
Class 2
S420
1.00
27.09 → 2
6.18 → 1
Class 2
S420
1.10
27.09 → 2
6.18 → 1
Class 2
S420
1.05
27.09 → 2
6.18 → 1
Class 2
S460
1.00
27.09 → 2
6.18 → 1
Class 2
S460
1.10
27.09 → 2
6.18 → 1
Class 2
S460
1.05
27.09 → 2
6.18 → 1
Class 2
Property Value
h (mm) 390
b (mm) 300
tw / tf (mm) 11 / 19
r (mm) 27
A (mm²) 12,580
Iy (cm⁴) 45,070
Iz (cm⁴) 8,560
Wel,y (cm³) 2311
Wpl,y (cm³) 2654
iy / iz (mm) 189.3 / 82.5
Design Resistances · γM0
Resistance Value
Npl,Rd 2,956.3 kN
Vpl,Rd 853.4 kN
Mpl,Rd 623.7 kNm
Mel,Rd 543.1 kNm
Resistance Value
Npl,Rd 2,687.5 kN
Vpl,Rd 775.8 kN
Mpl,Rd 567 kNm
Mel,Rd 493.7 kNm
Resistance Value
Npl,Rd 2,815.5 kN
Vpl,Rd 812.8 kN
Mpl,Rd 594 kNm
Mel,Rd 517.2 kNm
Resistance Value
Npl,Rd 3,459.5 kN
Vpl,Rd 998.7 kN
Mpl,Rd 729.9 kNm
Mel,Rd 635.5 kNm
Resistance Value
Npl,Rd 3,145 kN
Vpl,Rd 907.9 kN
Mpl,Rd 663.5 kNm
Mel,Rd 577.7 kNm
Resistance Value
Npl,Rd 3,294.8 kN
Vpl,Rd 951.1 kN
Mpl,Rd 695.1 kNm
Mel,Rd 605.3 kNm
Resistance Value
Npl,Rd 4,465.9 kN
Vpl,Rd 1,289.2 kN
Mpl,Rd 942.2 kNm
Mel,Rd 820.4 kNm
Resistance Value
Npl,Rd 4,059.9 kN
Vpl,Rd 1,172 kN
Mpl,Rd 856.5 kNm
Mel,Rd 745.8 kNm
Resistance Value
Npl,Rd 4,253.2 kN
Vpl,Rd 1,227.8 kN
Mpl,Rd 897.3 kNm
Mel,Rd 781.3 kNm
Resistance Value
Npl,Rd 5,283.6 kN
Vpl,Rd 1,525.2 kN
Mpl,Rd 1,114.7 kNm
Mel,Rd 970.6 kNm
Resistance Value
Npl,Rd 4,803.3 kN
Vpl,Rd 1,386.6 kN
Mpl,Rd 1,013.3 kNm
Mel,Rd 882.4 kNm
Resistance Value
Npl,Rd 5,032 kN
Vpl,Rd 1,452.6 kN
Mpl,Rd 1,061.6 kNm
Mel,Rd 924.4 kNm
Resistance Value
Npl,Rd 5,786.8 kN
Vpl,Rd 1,670.5 kN
Mpl,Rd 1,220.8 kNm
Mel,Rd 1,063.1 kNm
Resistance Value
Npl,Rd 5,260.7 kN
Vpl,Rd 1,518.6 kN
Mpl,Rd 1,109.9 kNm
Mel,Rd 966.4 kNm
Resistance Value
Npl,Rd 5,511.2 kN
Vpl,Rd 1,591 kN
Mpl,Rd 1,162.7 kNm
Mel,Rd 1,012.4 kNm
Pro feature
Running a full portal frame with 50+ members?
FrameAI Pro processes your entire PDF drawing set — extracts all members, classifies every section, runs member buckling, connection design, and outputs a fabrication-ready drawing with DSTV NC1 files.
See Pro plans →
← ← Back to calculator
HEA 400 — Cross-Section Classification & Resistances
This page shows pre-computed EN 1993-1-1 design values for the HEA 400 HEA section. The governing cross-section class is 2 (Class 2 — Compact), which determines whether the section may develop its full plastic moment capacity (Class 1–2) or is limited to the elastic moment (Class 3–4). Npl,Rd, Vpl,Rd, Mpl,Rd, and Mel,Rd are shown for all combinations of steel grade (S235 to S460) and national annex (EN γM0=1.00, NL γM0=1.10, DE γM0=1.05).