Engineering Disciplines — SECURITY
Physical Security Engineering
FrameAI Security reads your floor plan PDF and generates a complete physical security specification. EN 50132-7 CCTV coverage heat-maps (Axis/Hikvision FOV cones, pixel density at target, NVR storage, bandwidth model), EN 60839-11 access control matrices (card readers, mag-locks, REX), EN 50131 intrusion detection zoning, and risk assessment per EN 50131 Grade 1–4. Cable schedules and rack elevations ready for the installer.
FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →
🛡️
See It In Action
Security topology builder — CCTV zones, access control points, intrusion detection layers — visualised from your floor plan, no signup required.
Try security topology builder →
FrameAI vs Junior Engineer — Physical Security
| Task |
Junior engineer |
FrameAI |
| Floor plan → CCTV camera placement |
3–5 h |
< 2 min |
| EN 50132-7 pixel density analysis (per camera) |
30–60 min |
instant |
| NVR storage & bandwidth model |
1–2 h |
instant |
| Access control door schedule |
2–4 h |
< 1 min |
| EN 50131 intrusion detection zoning |
2–4 h |
< 2 min |
| Risk assessment (EN 50131 Grade) |
4–8 h |
< 3 min |
| Cable schedule (cameras + readers + detectors) |
3–6 h |
< 2 min |
Key Capabilities
▸
EN 50132-7 CCTV coverage heat-map — FOV cones (Axis/Hikvision), pixel density at target, PPF analysis
▸
NVR storage and bandwidth model — retention days, compression codec, bitrate per camera
▸
EN 60839-11 access control matrix — door schedule, credential types, mag-lock, REX wiring
▸
EN 50131 intrusion detection zoning — Grade 1–4, detector spacing, tamper zones, panel sizing
▸
Risk assessment per EN 50131 — threat classification, vulnerability scoring, countermeasure table
▸
Cable schedule export — camera, reader, detector, and lock wiring with conductor sizing
▸
Rack elevation — NVR, access control panel, UPS sizing, patch panel layout
▸
Fire alarm specification per EN 54-14 — detector spacing, zone allocation, cause-and-effect matrix
▸
EN 50133 access control compliance check — credential strength, dual authentication, audit trail
Worked Examples
"CCTV layout: 24 cameras (16× 2MP varifocal, 8× 4MP PTZ). Coverage: 94% of floor area ≥ 125 PPF (identification grade). NVR storage: 28 TB @ 30-day retention, H.265 compression."
EN 50132-7 CCTV coverage analysis output
Try security topology builder →
"Access control: 18 doors, 3 access levels, dual-factor on server room (card + PIN, EN 60839-11 §5.4). UPS: 1.2 kVA for 4-hour standby. Cable schedule: 1.8 km total wiring."
EN 60839-11 access control specification
Try security assessment →
Floor plan to full security specification — in minutes
CCTV heat-maps, access control matrices, intrusion zoning, and cable schedules — all from your building PDF. EN 50132 / EN 50133 / EN 50131 compliant output ready for the installer.
View Pricing →
FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →