Engineering Disciplines — SECURITY

Physical Security Engineering

FrameAI Security reads your floor plan PDF and generates a complete physical security specification. EN 50132-7 CCTV coverage heat-maps (Axis/Hikvision FOV cones, pixel density at target, NVR storage, bandwidth model), EN 60839-11 access control matrices (card readers, mag-locks, REX), EN 50131 intrusion detection zoning, and risk assessment per EN 50131 Grade 1–4. Cable schedules and rack elevations ready for the installer.

FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →

🛡️
See It In Action
Security topology builder — CCTV zones, access control points, intrusion detection layers — visualised from your floor plan, no signup required.
Try security topology builder →
FrameAI vs Junior Engineer — Physical Security
Task Junior engineer FrameAI
Floor plan → CCTV camera placement 3–5 h < 2 min
EN 50132-7 pixel density analysis (per camera) 30–60 min instant
NVR storage & bandwidth model 1–2 h instant
Access control door schedule 2–4 h < 1 min
EN 50131 intrusion detection zoning 2–4 h < 2 min
Risk assessment (EN 50131 Grade) 4–8 h < 3 min
Cable schedule (cameras + readers + detectors) 3–6 h < 2 min
Key Capabilities
EN 50132-7 CCTV coverage heat-map — FOV cones (Axis/Hikvision), pixel density at target, PPF analysis
NVR storage and bandwidth model — retention days, compression codec, bitrate per camera
EN 60839-11 access control matrix — door schedule, credential types, mag-lock, REX wiring
EN 50131 intrusion detection zoning — Grade 1–4, detector spacing, tamper zones, panel sizing
Risk assessment per EN 50131 — threat classification, vulnerability scoring, countermeasure table
Cable schedule export — camera, reader, detector, and lock wiring with conductor sizing
Rack elevation — NVR, access control panel, UPS sizing, patch panel layout
Fire alarm specification per EN 54-14 — detector spacing, zone allocation, cause-and-effect matrix
EN 50133 access control compliance check — credential strength, dual authentication, audit trail
Worked Examples
"CCTV layout: 24 cameras (16× 2MP varifocal, 8× 4MP PTZ). Coverage: 94% of floor area ≥ 125 PPF (identification grade). NVR storage: 28 TB @ 30-day retention, H.265 compression."
EN 50132-7 CCTV coverage analysis output
Try security topology builder →
"Access control: 18 doors, 3 access levels, dual-factor on server room (card + PIN, EN 60839-11 §5.4). UPS: 1.2 kVA for 4-hour standby. Cable schedule: 1.8 km total wiring."
EN 60839-11 access control specification
Try security assessment →
Free Calculators & Tools

Floor plan to full security specification — in minutes

CCTV heat-maps, access control matrices, intrusion zoning, and cable schedules — all from your building PDF. EN 50132 / EN 50133 / EN 50131 compliant output ready for the installer.

View Pricing →

FrameAI offers all disciplines as individual plans or bundled in cost-effective packages. View pricing →