Probleemomschrijving
RVB ligger b=300mm, h=500mm. Beton C30/37. Buigmoment M_Ed = 280 kNm. Schuif V_Ed = 180 kN.
Berekening Stappen — 5 stappen
§6.1
Buigwapening
Afleiding
A_s = 1605 mm2 required, 2454 mm2 provided -> 65% utilization
Formule
A_s = M_Ed/(0.87 f_yk z)
Resultaat
65% utilization
§6.2.3
Schuif V_Rd,c
Afleiding
V_Rd,c = 213 kN > 180 kN minimum links only
Formule
V_Rd,c = 0.12 k (100 rho f_ck)^{1/3} b_w d
Resultaat
213 kN > 180 kN -> PASS
§6.2.3
Minimale zwaluwstaarten
Afleiding
Use Ø8 @ 250mm two-leg links
Formule
s_max = A_sw/(rho_w,min b_w)
Resultaat
Ø8 @ 250mm PASS
§7.3
SLS doorbuiging
Afleiding
L/d = 11.56 > 11.15 -> compression steel needed
Formule
(L/d)_lim = 11.15
Resultaat
Add compression steel
§7.3
Herzien met drukwapening
Afleiding
3×20mm bars added -> (L/d)_lim = 32.4 > 11.56
Formule
(L/d)_lim = 32.4
Resultaat
32.4 > 11.56 -> PASS