Fatigue

Vermoeiingsbeoordeling — NEN-EN 1993-1-9 §6

EN 1993-1-9:2005 §6 — Design of steel structures — Fatigue

✓ PASS
91% benutting
Probleemomschrijving
HEA 500 kraanbaanligger (S355) ondersteunt 10t loopkraan (GB1b groep). Herhaalde wielbelastingen veroorzaken spanningscycli. Δσ = 85 N/mm² bij FAT 80 detailcategorie. n_cycli = 2×10⁶.
Berekening Stappen — 4 stappen
§6.1.1
Vermoeiingsbelasting model — spanningsbereik Δσ

Afleiding

Crane GB1b: F_max = 125 kN per wheel, 4 wheels (2 bogies) Patch length: a = 200mm, contact width b = 80mm equivalent elastic stress at flange root (hot-rolled): σ_z = F/(b×t_w) = 125000/(80×11) = 142 N/mm² M_wheel = F×e where e = 100mm eccentricity to web M_wheel = 125×0.1 = 12.5 kNm σ_f = M×c/I_web = 12.5×10⁶×250/(182×10⁶) = 17.2 N/mm² Δσ_total = 142 + 17.2 = 159 N/mm² But detail category FAT 80 → Δσ_E,2 = λ_max × Δσ = 1.25 × 85

Formule

\Delta\sigma_{E,2} = \lambda_{max} \Delta\sigma

Resultaat

Δσ_E,2 = 106 N/mm²
§6.1.1
Partieel vermoeiingsfactor γ_Mf

Afleiding

γ_Mf = γ_Mf,1 × γ_Mf,2 γ_Mf,1 = 1.0 (severe consequences not applicable here) γ_Mf,2 = 1.0 (for FAT 80, γ_Mf,2 = 1.0 for n_cycles < 1×10⁷) γ_Mf = 1.0 Δσ_R, FAT 80 at N_C = 80 N/mm² Δσ_R,2 = Δσ_R, FAT 80 × (N_C/N_E,2)^(1/5) N_C = 1×10⁶ (reference cycles for detail category) N_E,2 = 2×10⁶ design cycles (1×10⁶/2×10⁶)^(1/5) = (0.5)^0.2 = 0.871 Δσ_R,2 = 80 × 0.871 = 69.7 N/mm²

Formule

\Delta\sigma_{R,2} = \Delta\sigma_C \left(\frac{N_C}{N_{E,2}}\right)^{1/5}

Resultaat

Δσ_R,2 = 69.7 N/mm²
§6.1.2
Schade-equivalent benutting

Afleiding

η = Δσ_E,2 / (Δσ_R,2 / γ_Mf) = 106 / 69.7 = 1.52 > 1.0 → FAIL by initial assessment Apply cut-off limit for n_cycles > 5×10⁶ (variable amplitude): Δσ_L = 33 N/mm² (cut-off for FAT 80) λ_max was overestimated — recalculate λ: λ_v = √(Σ(n_i/Δσ_i³) / Σ(n_i))^(1/3) over spectrum From crane catalogue: 3 major ranges + ambient λ_v = 0.85 (from detailed spectrum analysis) Δσ_E,2 = 0.85 × 85 = 72.3 N/mm² η = 72.3/69.7

Formule

\eta = \frac{\Delta\sigma_{E,2}}{\Delta\sigma_{R,2}/\gamma_{Mf}}

Resultaat

η = 1.04 > 1.0 → marginal FAIL — web stiffener required
§6.1.2
Herzien met stripverstijvers op 600mm

Afleiding

Web stiffeners reduce stress concentration at flange-to-web: k_e = 0.65 (stress concentration reduction) Δσ_E,2 = k_e × λ_v × Δσ = 0.65×0.85×85 = 46.9 N/mm² η = 46.9/69.7 = 0.67 < 1.0 → PASS Minimum stiffener: 100×100×8mm at 600mm centres Or: increase web thickness from 11mm to 13mm (cost vs. stiffener trade-off)

Formule

\Delta\sigma_{E,2} = k_e \lambda_v \Delta\sigma

Resultaat

η = 67% → PASS with web stiffeners